Page 13 - Wexler Ophthalmic Catalog
P. 13

XII     INTRODUCTION                                                              CUTTING EDGE                                 TECHNOLOGY                                                               INTRODUCTION                 XIII
                   INTRODUCTION
                                                                                                                                                                                                                    INTRODUCTION









     Stainless Steel & Titanium                                                                                                              Stainless Steel & Titanium
     DIAMOND & DISPOSABLE KNIVES                                                                                                             Vitreoretinal Surgery

     INSTRUMENT SPECIFICATIONS                                                                                                               INSTRUMENT SPECIFICATIONS



     Titanium handles                                                                                                                                                                                        Micro Incision Instruments
                                                                                                                                                                                                            Wexler Micro Incision instruments are designed
                                                                       Our  Knives  are  equipped  with  a  Titanium                                                                                        to perform Micro Incision surgery techniques.
                                                                       Handle which allows the surgeon to perform
                                                                       precise movements without adding the weight                                                                                          MICS  instruments  consist  of  a  Universal
                                                                       of a standard stainless steel instrument.                                                                                            Titanium handle and a detachable working tip.
                                                                                                                                                                                                            The handle fits all tip sizes reducing the cost of
                                                                                                                                              VL0402.3                       VL0422.3                       these instruments.

                                                                                                                                                                                                            Tips come in three different sizes, 20, 23 and 25
                                                                                                                                                                                                            Gauge which can be detached from the handle
                                                                                                                                                                                                            facilitating the cleaning process and increasing
                                                                                                                                                                                                            its durability.

                                                                                                                                                                                                            Custom Orders

                                                                                                                                                                                                            MICS instruments can be manufactured upon
                                                                                                                                              VL0400.2                                                      request as a Solid, One Piece unit.
     Real Diamond Blades
                                                                                                                                             25 Gauge Tip            23 Gauge Tip          20 Gauge Tip     Cleaning and Sterilization
                                                                       The  diamonds  in  Wexler  Knives  are  real
                                                                       diamonds, which are known to retain an edge                                                                                          MICS instruments should be washed with
                                                                       that will stay sharper than GEM quality blades.                                                                                      distilled warm water (30ºC-40ºC / 86ºF-104ºF)
                                                                                                                                                                                                            immediately after surgery.

                                                                                                                                                                                                               1. Disconnect the Working Tip from
                                                                                                                                                                                                                 Handle
     Tip Sizes                                                                                                                                VL2008.3               VL1030.3              VL0426.3              2. Screw the Cleaning  Adaptor (VL002.1)
                                                                                                                                                                                                                 onto the base of the tip
                                                                       Wexler’s  Diamond  blades  are  available  in                                                                                           3. Plug a 50-100ml syringe filled with
                                                                       different  sizes  for  a  precise  incision  width                                                                                        warm distilled water onto the adaptor
                                                                       for  each  individual  surgical  procedure.  1mm                                                                                          and push the plunger to flush the inner
                                                                       blades  are  ideal  for  General,  Sideport  and                                                                                          shaft
                                                                       Relaxing  incisions  that  are  often  used  in                                                                                         4. Repeat above procedure (Step 3) with
                                                                       Refractive surgeries. 2.0-3.2mm blades are best                                                                                           Alcohol to remove any moisture from
                                                                       for use with Keratome or Phaco incisions and                                                                                              shaft
                                                                       are ideal for cataract surgeries.  Crescent blades                                                                                      5. Use the syringe 2 to 3 times to push
                                                                       are perfect for use in tunnel incisions.
                                                                                                                                                                                                                 compressed air to completely dry the
                                                                                                                                                                                                                 inner shaft
                                                                                                                                                                                                               6. Wash the Handle with warm distilled
                                                                                                                                                                                                                 water and dry it at room temprature
                                                                                                                                                                                                               7. Sterilize instruments in ETO, Autoclave
                                                                                                                                                                                                                 or Dry-head procedure following the
                                                                                                                                                                                                                 standard procedures.






                                                                               Tel 713.723.6900  •  800.414.1076  •  Fax 713.723.6906    Tel 713.723.6900  •  800.414.1076  •  Fax 713.723.6906
                                                                           email: sales@wexlersurgical.com  •  www.wexlersurgical.com    email: sales@wexlersurgical.com  •  www.wexlersurgical.com
   8   9   10   11   12   13   14   15   16   17   18